鮑米勒驅(qū)動(dòng)器開(kāi)不了機(jī)維修:
719:Timeout during motor identification電機(jī)識(shí)別超時(shí)。
Error during identification of motor parameters. The maximum permitted phase voltage (= 80 V) was exceeded during the resistance measurement.識(shí)別電機(jī)參數(shù)時(shí)出錯(cuò)。在電阻測(cè)量過(guò)程中,超過(guò)了每個(gè)允許相的最大電壓(=80V)。
Possible cause: 原因:
Incorrect motor nominal current setting in Parameter 107.09.
參數(shù)107.09中的電機(jī)標(biāo)稱電流設(shè)置不正確。
Effect: Output voltage set to ZERO to protect the motor. An additional drive block occurs with standard error response.
效果:輸出電壓設(shè)置為零,以保護(hù)電機(jī)。附加的驅(qū)動(dòng)器塊出現(xiàn)標(biāo)準(zhǔn)錯(cuò)誤響應(yīng)。
Resetting after error elimination: 錯(cuò)誤消除后重置:
Error reset is possible. Timeout (45 seconds) with R measurement with motor parameter identification, such as due to error during current / voltage measurement or normalization or limit value.錯(cuò)誤重置是可能的。電機(jī)參數(shù)識(shí)別的R測(cè)量超時(shí)(45秒),例如由于電流/電壓測(cè)量或標(biāo)準(zhǔn)化或限值過(guò)程中的錯(cuò)誤。
鮑米勒驅(qū)動(dòng)器常見(jiàn)故障修理維護(hù):
baumullre鮑米勒BM4434-SI1-01242-0311-7012維修,
羅蘭BAUMULLER(鮑米勒) BUM617-12/18-31羅蘭印刷機(jī)墨轆驅(qū)動(dòng)器維修,
BAUMULLER苞米勒鮑米勒伺服驅(qū)動(dòng)器BUG3-35-31-B-010 BUG3-35維修,
BAUMULLER鮑米勒BUS 6V主板BUS6-VC-AC-0067維修,
3.9511D BAUMULLER鮑米勒板卡鮑米勒伺服鮑米勒電機(jī)鮑米勒驅(qū)動(dòng)器維修,
鮑米勒驅(qū)動(dòng)BUM25-30/60-30-0001 鮑米勒BAUMULLER伺服驅(qū)動(dòng)器維修,
鮑米勒DF30K-IEC71-DS 56-B2維修,
Baumuller鮑米勒伺服驅(qū)動(dòng)器BUM618-12/18-31-R-0010-C010-SM維修,
鮑米勒伺服驅(qū)動(dòng)器 BM4423-St1-01242-0311-7012維修,
鮑米勒 BUS21L-7.5/15-31-224 BUG2-60-31-B-209維修,
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修
本文鏈接:http://www.ncjyxx.com/fuwu/Services_Show23636.htm
伺服驅(qū)動(dòng)器維修 伺服電機(jī)維修 觸摸屏維修 變頻器維修
聯(lián)系方式:
電話:021-50157782
手機(jī):13817011982 微信同號(hào)
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.ncjyxx.com
【 我們確保修好測(cè)試好給客戶。。。
上一篇:金華市測(cè)試臺(tái)發(fā)那科觸摸屏A20B系列PWR燈不亮--維修售后點(diǎn)
下一篇:沒(méi)有了