英格瑪特/力士樂伺服驅(qū)動(dòng)器故障維修:控制器是針對(duì)伺服電機(jī)特殊使用而的,也可能專為某些產(chǎn)品而制造,選用哪種控制信形式因設(shè)計(jì)師個(gè)人規(guī)劃理念而定,或選用控制器與驅(qū)動(dòng)器一體規(guī)劃,絡(luò)式遠(yuǎn)程控制,這些不是通用伺服電機(jī)評(píng)論的規(guī)模,但工作理論及工作形式是相同的。
DDS02.2-W驅(qū)動(dòng)器F262輸出處故障修理:
F262 External Short at Status Outputs
狀態(tài)輸出處的外部短路
Description:說明:Status outputs are monitored for short circuits and thermal overload.監(jiān)測(cè)狀態(tài)輸出是否存在短路和熱過載。
• If output current exceeds 350mA for about 1μs, then this is acknowledged as a short circuit and the pertinent channel is shut off.
•如果輸出電流超過350mA約1μs,則為確認(rèn)為短路,并關(guān)閉相關(guān)通道。
The output remains off unti the error is cleared.
在清除錯(cuò)誤之前,輸出保持關(guān)閉。
• With thermal overload, the error is set and the output(s) shut off. After
the driver has cooled off, the outputs are switched back on and so on.
•熱過載時(shí),設(shè)置錯(cuò)誤并關(guān)閉輸出驅(qū)動(dòng)器已經(jīng)冷卻,輸出重新打開,等等。
The error, however, remains until it is cleared. Thermal overload can
occur if several outputs are overloaded in excess of 80 mA.然而,該錯(cuò)誤將一直存在,直到清除為止。熱過載可能如果多個(gè)輸出過載超過80mA。
Cause:原因:
1. Short circuited outputs (X2/6, X2/7, X2/8, X2/9, X2/10, X2/20,X2/21, X2/22)
短路輸出(X2/6、X2/7、X2/8、X2/9、X2/10、X2/20、X2/21,X2/22)
2. One or more outputs are overloaded.
一個(gè)或多個(gè)輸出過載。
Remedy:解決措施:
For 1. Eliminate short circuit or limit switching current (< 350 mA)
對(duì)于1。消除短路或限制開關(guān)電流(<350 mA)
For 2. Drop current, depending on output, to < 80 mA.
對(duì)于2。根據(jù)輸出,將電流降至<80 mA。
友情提示:請(qǐng)勿自行拆卸檢查或交給非專業(yè)人士,以免越修越壞,造成不必要的經(jīng)濟(jì)損失!早一天聯(lián)系,少一天損失!上海仰光電子科技有限公司 因?yàn)閷W,所以專業(yè)!
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修
本文鏈接:http://www.ncjyxx.com/fuwu/Services_Show23126.htm
伺服驅(qū)動(dòng)器維修 伺服電機(jī)維修 觸摸屏維修 變頻器維修
聯(lián)系方式:
電話:021-50157782
手機(jī):13817011982 微信同號(hào)
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.ncjyxx.com
【 我們確保修好測(cè)試好給客戶!。。
上一篇:ABB變頻器ACS355系列故障報(bào)警2312如何解決故障/上海仰光
下一篇:沒有了