力士樂伺服驅(qū)動器修理:F219 Motor Overtemperature Shutdown電機過熱停機。上海仰光電子科技有限公司專業(yè)從事各品牌伺服驅(qū)動器維修,伺服電機維修,觸摸屏維修,變頻器維修,伺服器維修,伺服控制器維修,數(shù)控系統(tǒng)維修改造,機器人維修保養(yǎng)以及各種板卡,芯片級維修維護,免費檢測,快速維修,部分立等可取!
力士樂伺服放大器維修:
Description:說明:
Motor temperature has risen to an unacceptable level. As soon as
temperature threshold (155°C) is exceeded, the drive will immediately be
brought to a standstill as set in the error reaction (P-0-0119, best possible
standstill).
電機溫度已升至不可接受的水平。一旦超過溫度閾值(155°C),驅(qū)動器將立即按照錯誤反應(P-00119,最好是靜止)。
It applies:適用于:
temperature warning threshold < temperture error threshold
溫度警告閾值<溫度錯誤閾值
Cause:原因:
1. The motor was overloaded. The effective torque demanded from the motor was above its allowable continuous torque level for too long.
電動機過載。電機所需的有效扭矩超過其允許的持續(xù)扭矩水平太長時間。
2. Break in line, ground short or short circuit in the motor temperature monitor line。電機溫度監(jiān)測器線路中的線路斷路、接地短路或短路
3. Instability in the velocity loop
速度回路中的不穩(wěn)定性
Remedy:
For 1. Check the installation of the motor. If the system has been in operation for a long time, check to see if the the operating conditions have changed. (in regards to pollution, friction, moved components, etc.)檢查電機的安裝情況。如果系統(tǒng)已運行很長時間,請檢查操作條件是否發(fā)生變化。(關于污染、摩擦、移動部件等)
For 2. Check wires and cables to the motor temperature monitor for wire breaks, earth short and short circuits.
檢查電機溫度監(jiān)測器的電線和電纜是否斷線、接地短路和短路。
For 3. Check velocity loop parameters.
檢查速度回路參數(shù)。
力士樂伺服放大器維修:同城速修快修地址:上海嘉定區(qū)博園路858號531-532.維修流程:
第1步:根據(jù)客戶的故障描述,評估該伺服器的可修復性。
第2步:客戶寄/送到我司,登記入庫,等待檢測。
第3步:工程師檢測故障點,出具檢測報告書,確定維修價格及維修周期。
第4步:維修報價,等待客戶確認。同意則進行維修,不同意則原機返回。
第5步:維修ok, 帶電機測試老化。
第6步:試機成功登記出庫。
第7步:客戶付款。
第8步:交付客戶使用。
第9步:貼心的跟蹤服務。
轉載請注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動器維修,伺服電機維修
本文鏈接:http://www.ncjyxx.com/fuwu/Services_Show14520.htm
伺服驅(qū)動器維修 伺服電機維修 觸摸屏維修 變頻器維修
電話:021-50157782
手機:13817011982 微信同號
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.ncjyxx.com
【 我們確保修好測試好給客戶。。!】
下一篇:沒有了